Mezzanines/Equipment platform

12 Mar.,2024

 

Re: Mezzanines/Equipment platform

505.5 specifically excludes an equipment platform from being called a mezzanine so I don't believe 505.1 is applicable as that is specific to mezzanines.

EQUIPMENT PLATFORM. An unoccupied, elevated platform used exclusively for mechanical systems or industrial process equipment, including the associated elevated walkways, stairs and ladders necessary to access the platform (see Section 505.5).

505.5 Equipment platforms.

Equipment platforms in buildings shall not be considered as a portion of the floor below. Such equipment platforms shall not contribute to either the building area or the number of stories as regulated by Section 503.1. The area of the equipment platform shall not be included in determining the fire area.

Equipment platforms shall not be a part of any mezzanine and such platforms and the walkways, stairs and ladders providing access to an equipment platform shall not serve as a part of the means of egress from the building.



With that said I think 1208.2 might be the correct code section to require a 7 ft ceiling for an un-occupied space but others may differ on that

1208.2 Minimum ceiling heights.

Occupiable spaces, habitable spaces and corridors shall have a ceiling height of not less than 7 feet 6 inches (2286 mm). Bathrooms, toilet rooms, kitchens, storage rooms and laundry rooms shall be permitted to have a ceiling height of not less than 7 feet (2134 mm).

If you have any questions on mezzanine storage systems. We will give the professional answers to your questions.